Appendix A Troubleshooting
A.2
In the Case Where RCI Status of RCI Host
Changes From ACTIVE to INACTIVE
Remarks: When this problem has occurred, do not replace the XSCF unit because it
This problem is occurred by the mistake of the RCI construction procedure and the
RCI connection.
t occurrs when the same RCI address is set and constructed, or, when connecting with
the RCI network of the construction of the RCI host that has not been initialized.
Confirm whether to correspond to this problem. The procedure is the following:
1 Excute showlogs command, and check whether RCI configuration conflict is
generated in error log.
2 When that message was generated, check the RCI establishment procedure,
the RCI address value and the connection.
3 In the case of anomaly, correct the RCI address or the connection of relevant
device according to the change procedure of each device.
4 Refer to
establishment.
A-4
is not a failure of the XSCF unit.
Chapter 1.3.4, "When a RCI Host is added later"
and retry RCI