Fujitsu SPARC Enterprise M8000 Notes sur le produit - Page 43
Parcourez en ligne ou téléchargez le pdf Notes sur le produit pour {nom_de_la_catégorie} Fujitsu SPARC Enterprise M8000. Fujitsu SPARC Enterprise M8000 44 pages. For xcp version 1041
Également pour Fujitsu SPARC Enterprise M8000 : Manuel de démarrage (4 pages), Caractéristiques Manuel (30 pages), Manuel complémentaire (36 pages)
Documentation Updates (Continued)
TABLE 7
Title
SPARC Enterprise
M4000/M5000/M8000/
M9000 Servers Dynamic
Reconfiguration (DR)
User's Guide
Page Number
2-27
2.5 "Operation Management"
The following sections will be added:
2.5.6, "XSCF Failover"
An XSCF failover might prevent a DR operation from
completing. To check, log in to the active XSCF, check the status
of the system board and, if necessary, repeat the DR operation.
2.5.7, "Kernel Memory Board Deletion"
If an XSCF failure or failover occurs during the Copy-rename
phase of a deleteboard(8) or moveboard(8) operation, the
Solaris OS may panic and display the following message:
Irrecoverable FMEM error error_code
If you see this message, log in to the XSCF again to check status.
You may have to reboot the Solaris OS and, on the XSCF, check
system board status, specify the kernel memory board, and
repeat the DR operation.
2.5.8, "Deletion of Board with DVD Drive"
To delete the system board to which the server's DVD drive is
connected, execute the following steps:
1. Stop the vold(1M) daemon by disabling the volfs service.
# /usr/sbin/svcadm disable volfs
2. Execute the DR operation.
3. Restart the vold(1M) daemon by enabling the volfs service.
# /usr/sbin/svcadm enable volfs
For details, see the vold(1M) Solaris man page.
Update
SPARC Enterprise M8000/M9000 Servers Product Notes
33