Parcourez en ligne ou téléchargez le pdf Manuel de l'opérateur pour {nom_de_la_catégorie} Fujitsu M3096E+. Fujitsu M3096E+ 45 pages. Image scanner
2.8
Dynamic Threshold
Circuit or Image Processing
Circuit Option Installation
2.8.1
DTC installation
(1)
Remove the main control PCA
Loosen the front cover screw and remove the front cover from the scanner.
Remove the screws "C" and "D", the board support, and the F-plate.
(Do not remove the nickel cloth from the F-plate.)
Remove all connectors on the front end of the PCA.
Hold clamps at both ends of the PCA with hands and pull toward you.
/
F-plate
\
Front cover
Screws D
nl3
0
'
I
Screw C
Outer view of board support
Figure 2.8
Main control PCA removal
60FHS020E-01