Fujitsu ETERNUS2000 model 100 Manuel - Page 24

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Fujitsu ETERNUS2000 model 100. Fujitsu ETERNUS2000 model 100 28 pages. Disk storage system
Également pour Fujitsu ETERNUS2000 model 100 : Manuel de connexion au serveur (25 pages), Manuel de connexion au serveur (32 pages), Manuel de connexion (19 pages), Manuel de connexion (31 pages)

Fujitsu ETERNUS2000 model 100 Manuel
Chapter 9
9.1

Enabling MPxIO

Enable MPxIO.
Check the [mpxio-disable="no"] line in the "/kernel/drv/iscsi.conf" file.
Change the parameter to "no" when "yes" is set.
Example for changing the "/kernel/drv/iscsi.conf" file:
# To globally enable MPxIO on all iscsi ports set:
# mpxio-disable="no";
#
# To globally disable MPxIO on all iscsi ports set:
# mpxio-disable="yes";
#
mpxio-disable="no";
9.2

Reconfiguring and Restarting the Server

Reconfigure and restart the server to effect the new settings.
# touch /reconfigure
# /usr/sbin/shutdown -y -g0 -i6
Use the "format" command to check the MPxIO multipath status after multipathing is set up.
P3AM-4182-03ENZ0
Server Connection Guide (iSCSI) for Oracle Solaris
Setting Up the Multipath Configuration
For the iSCSI LAN (used to transfer data), do not set multipath
configuration with IP Network Multipathing (IPMP).
When configuring the multipath, use MPxIO in the same way as FC-SAN is
used for configuration.
<- Check that no is set.
24
Copyright 2010 FUJITSU LIMITED