Fujitsu D2530 Manuel technique - Page 19
Parcourez en ligne ou téléchargez le pdf Manuel technique pour {nom_de_la_catégorie} Fujitsu D2530. Fujitsu D2530 35 pages. For econel 200 s2
Features
Temperature / system monitoring
Fan control
The fans are controlled according to temperature.
Sensor monitoring
The removal of, or a fault in, a temperature sensor is detected. Should this
happen all fans monitored by this sensor run at maximum speed, to achieve the
greatest possible protection of the hardware.
Voltage monitoring
The most important voltages are monitored. When a voltage exceeds warning
level high or falls below warning level low an alert will be generated. Adequate
measurements can be done by running agents.
Cover monitoring
Unauthorised opening of the cover is detected, even when the system is
switched off. However, this will only be indicated when the system is switched
on again
System Event Log (SEL)
All monitored events of the system board are recorded in the System Event Log.
They could be retrieved after a system reboot via ServerView.
Technical Manual
19
D2530 (Econel 200 S2)