3. COMPONENTS:

Heater
Drain pump
The drain pump in this machine is connected
independently from the wash motor (the previous
machines had a series connection).
Service Manual
Seven Digit - 2005
The new heater is 1800 Watt - powered (the old one:
2040 Watt) and operates at a tension equal to 230
Volt and 7,8 Amp, at a resistance equal to 29,4 Ohm.
Moreover the pump is shielded by an automatic-
restoration thermal protector, which operates in case
of overheating or blockage of the pump.
There are two types of thermal protector:
15AM211 A
on
off
placed in the middle of the coil
7AMO31AS
on
off
next to the coil
Edition
2005.07.06
150° ±
5°C
105° ±
15°C
120° ±
5°C
76°
±
15°C