• the mains cable is wired directly into a 13 amp
GB
cable outlet, controlled by a switch, (in
compliance with BS 5733) which is accessible
without moving the appliance.
! ! ! ! ! For appliances with a rating greater than 13 amp
(eg: electric hob, double ovens and freestanding
electric cookers etc.) the mains cable must be wired
into a cooker output point with a rating of 45 amp. In
this case the cable is not supplied.
Disposing of the plug:
Ensure that before disposing of the plug itself, you
make the pins unusable so that it cannot be
accidentally inserted into a socket. Instructions for
connecting cable to an alternative plug:
! ! ! ! ! The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
If the colours of the wires in the mains lead do not
correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
Connect Green & Yellow wire to terminal marked "E E E E E "
or or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked "L L L L L " or
coloured Red.
Connect Blue wire to terminal marked "N N N N N " or
coloured Black.
If a 13 amp plug (BS 1363) is used it must be fitted
with a 13 amp fuse. A 15 amp plug must be
protected by a 15 amp fuse, either in the plug or
adaptor or at the distribution board. If you are in any
doubt about the electrical supply to your machine,
consult a qualified electrician before use.
How to connect an alternative plug:
The wires in this mains lead are coloured in
accordance with the following code:
B L U E
B L U E
B L U E
B L U E
B L U E
B R O W N
B R O W N
B R O W N
B R O W N
B R O W N
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
GREEN AND YELLOW
GREEN &
YELLOW
BROWN
BLUE
4
- Earth
- Neutral
- Live
"NEUTRAL
NEUTRAL
NEUTRAL" ("N N N N N ")
NEUTRAL
NEUTRAL
LIVE
LIVE
LIVE" ("L L L L L ")
"LIVE
LIVE
"EARTH
EARTH
EARTH" ("E E E E E ")
EARTH
EARTH
13 amp fuse
CROSS-BAR
CORD GRIP
Disposing of the appliance
When disposing of the appliance please remove the
plug by cutting the mains cable as close as
possible to the plug body and dispose of it as
described above.
Checking the connection for leaks
When the installation process is complete, check
the hose fittings for leaks using a soapy solution.
Never use a flame.
Adapting to different types of gas
It is possible to adapt the appliance to a type of gas
other than the default type (this is indicated on the
rating label on the cover).
Adapting the hob
Replacing the nozzles for the hob burners:
1. Remove the hob grids and
slide the burners off their
seats.
2. Unscrew the nozzles using
a 7 mm socket spanner ( see
figure ), and replace them with
nozzles suited to the new type
of gas ( see Burner and nozzle
specifications table ).
3. Replace all the components by following the
above instructions in reverse.
Adjusting the hob burners' minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory
screw, which is positioned inside or next to the tap
pin, until the flame is small but steady.
! If the appliance is connected to a liquid gas
supply, the regulatory screw must be fastened as
tightly as possible.
3. While the burner is alight, quickly change the position
of the knob from minimum to maximum and vice versa
several times, checking that the flame is not
extinguished.