Indesit K 601 V.C/G Manuel d'instructions pour l'installation et l'utilisation - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions pour l'installation et l'utilisation pour {nom_de_la_catégorie} Indesit K 601 V.C/G. Indesit K 601 V.C/G 12 pages. Indesit cooker with electric ventilated oven instructions for installation and use

Indesit K 601 V.C/G Manuel d'instructions pour l'installation et l'utilisation
Important: before making any adjustements, maintenance
etc. to the cooker, first ensure that it is disconnected from
the electricity supply.
Positioning
The appliance can therefore be installed next to cabinets,
provided the height does not exceed that of the hob.
Levelling
In order to have a perfect levelling of the cooker adjustable
feets are supplyed. They can be screwed in the seats
positioned in the corners of the cooker base.
Electrical connection
Electric cookers come without a power supply cable. The
cooker is designed to operate on an electricity supply
which conforms to the electrical data shown on the Rating
Plate. The cooker can be connected to the mains only
after removing the back panel of the cooker itself with a
screwdriver.
N.B.: the following installation procedure must be carried
out by a qualified electrician. The electrical installation must
comply with the IEE Regulations, Building & local By-Lays.
For the installation of the feeding cable carry out the
following operations:
Unscrew screw "V" (see fig. A)
Pull and open the junction blok lid
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Green & Yellow wire to terminal marked "E" or
coloured Green or Green & Yellow.
Brown wire to terminal marked "L" or coloured Red.
Blue wire to terminal marked "N" or coloured Black (see
fig. B).
fix the feeding cable in the special cable stop and close
the cover.

Installation

Earth
Neutral
Live
N.B.: the power supply cable must have these minimum
requirements:
Type:
H05RR-F
Section: 3x4 mm
V
Fig. A
Connecting the supply cable to the mains
WARNINGS: THIS APPLIANCE MUST BE EARTHED.
Important: The cooker must be connected to the mains
by a switched (double pole) cooker outlet correctly fused
with a capacity appropriate to that shown on the cooker
Rating Plate. All electrical wiring from the consumer unit
to the cooker, via the switched double pole cooker outlet,
must be of an acceptable type and current rating as above.
Note: the supply cable must be positioned so that it never
reaches at any point a temperature 50°C higher than the
room temperature. The cable must be routed away from
the rear vents.
or
4
2
Fig. B
HOT PARTS