Indesit K6T21/AUS Manuel d'utilisation - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Indesit K6T21/AUS. Indesit K6T21/AUS 12 pages. Indesit k6t21/aus cooker operating instructions
AUS
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of
the correct colour as indicated by the coloured
marking or the colour that is embossed in words on
the base of the plug. Replacements can be obtained
directly from your nearest Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded plug
and you should wish to remove it to add a cable
extension or to re-route the mains cable through
partitions, units etc., please ensure that either:
• the plug is replaced by a fused 13 amp re-
wireable plug bearing the BSI mark of approval.
or:
• the mains cable is wired directly into a 13 amp
cable outlet, controlled by a switch, (in
compliance with BS 5733) which is accessible
without moving the appliance.
! ! ! ! ! For appliances with a rating greater than 13 amp
(eg: electric hob, double ovens and freestanding
electric cookers etc.) the mains cable must be wired
into a cooker output point with a rating of 45 amp. In
this case the cable is not supplied.
Disposing of the plug:
Ensure that before disposing of the plug itself, you
make the pins unusable so that it cannot be
accidentally inserted into a socket. Instructions for
connecting cable to an alternative plug:
! ! ! ! ! The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
If the colours of the wires in the mains lead do not
correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
Connect Green & Yellow wire to terminal marked "E E E E E "
or or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked "L L L L L " or
coloured Red.
Connect Blue wire to terminal marked "N N N N N " or
coloured Black.
If a 13 amp plug (BS 1363) is used it must be fitted
with a 13 amp fuse. A 15 amp plug must be
protected by a 15 amp fuse, either in the plug or
adaptor or at the distribution board. If you are in any
doubt about the electrical supply to your machine,
consult a qualified electrician before use.
4
- Earth
- Neutral
- Live
How to connect an alternative plug:
The wires in this mains lead are coloured in
accordance with the following code:
GREEN &
YELLOW
13 amp fuse
BROWN
CROSS-BAR
BLUE
CORD GRIP
Disposing of the appliance
When disposing of the appliance please remove the
plug by cutting the mains cable as close as
possible to the plug body and dispose of it as
described above.
Checking the connection for leaks
When the installation process is complete, check
the hose fittings for leaks using a soapy solution.
Never use a flame.
Adapting to different types of gas
It is possible to adapt the
appliance to a type of gas
other than the default type
(this is indicated on the rating
label on the cover).
Adapting the hob
Replacing the nozzles for the hob burners:
1. Remove the hob grids and slide the burners off
their seats.
2. Unscrew the nozzles using a 7 mm socket
spanner ( see figure ), and replace them with nozzles
suited to the new type of gas ( see Burner and nozzle
specifications table ).
3. Replace all the components by following the
above instructions in reverse.
Adjusting the hob burners' minimum setting:
1. Turn the tap to the minimum position.
2. Remove the knob and adjust the regulatory
screw, which is positioned inside or next to the tap
pin, until the flame is small but steady.
B L U E
B L U E
B L U E
B L U E
B L U E
"NEUTRAL
NEUTRAL
NEUTRAL
NEUTRAL" ("N N N N N ")
NEUTRAL
B R O W N
B R O W N
B R O W N
B R O W N
B R O W N
"LIVE
LIVE
LIVE" ("L L L L L ")
LIVE
LIVE
GREEN AND
GREEN AND
GREEN AND
GREEN AND
GREEN AND
Y E L L O W
Y E L L O W
Y E L L O W
Y E L L O W
Y E L L O W
"EARTH
EARTH
EARTH" ("E E E E E ")
EARTH
EARTH