CONNECTING TO GAS SUPPLY
The cooker is designed to match the depth of standard 600mm worktops. An adaptor
backplate should, therefore, be fitted within the shaded area shown to allow the
cooker to be pushed fully to the wall.
70mm
GAS
BACKPLATE
POSITION
450mm
Connection to the cooker should be made with an approved appliance flexible
connection to BS 669. A length of 0.9 to 1.25m is recommended. The length of hose
chosen should be such that when the cooker is in situ, the hose does not touch the
floor.
The temperature rise of areas at the rear of the cooker that are likely to come in
contact with the flexible hose do not exceed 70˚C.