AEG SCB618F3LF Manuel de l'utilisateur - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} AEG SCB618F3LF. AEG SCB618F3LF 24 pages.
Également pour AEG SCB618F3LF : Manuel de l'utilisateur (20 pages)

AEG SCB618F3LF Manuel de l'utilisateur
8
www.aeg.com
Space required in use ²
B
² the height, width and depth of the
appliance including the handle, plus the
space necessary for free circulation of
the cooling air
Overall space required in use ³
H3 (A+B)
W3
D3
³ the height, width and depth of the
appliance including the handle, plus the
space necessary for free circulation of
the cooling air, plus the space necessary
to allow door opening to the minimum
angle permitting removal of all internal
equipment
3.2 Location
To ensure appliance's best functionality,
you should not install the appliance in the
nearby of the heat source (oven, stoves,
radiators, cookers or hobs) or in a place
with direct sunlight. Make sure that air
can circulate freely around the back of
the cabinet.
This appliance should be installed in a
dry, well ventilated indoor position.
This appliance is intended to be used at
ambient temperature ranging from 10°C
to 43°C.
The correct operation of the
appliance can only be
guaranteed within the
specified temperature range.
If you have any doubts
regarding where to install the
appliance, please turn to the
vendor, to our customer
service or to the nearest
Authorised Service Centre.
mm
36
mm
1816
mm
780
mm
1085
It must be possible to
disconnect the appliance
from the mains power
supply. The plug must
therefore be easily
accessible after installation.
3.3 Electrical connection
• Before plugging in, ensure that the
voltage and frequency shown on the
rating plate correspond to your
domestic power supply.
• The appliance must be earthed. The
power supply cable plug is provided
with a contact for this purpose. If the
domestic power supply socket is not
earthed, connect the appliance to a
separate earth in compliance with
current regulations, consulting a
qualified electrician.
• The manufacturer declines all
responsibility if the above safety
precautions are not observed.
• This appliance complies with the
E.E.C. Directives.
3.4 Ventilation requirements
The airflow behind the appliance must be
sufficient.
min.
5 cm
200 cm
CAUTION!
Refer to the installation
instructions for the
installation.
3.5 Door reversibility
Please refer to the separate document
with instructions on installation and door
reversal.
2
min.
2
200 cm