10
Connect the inlet supply pipe
to the inlet connector using
the compression nut and olive
(supplied). Always provide
mechanical support when making
plumbing connections. Upon
completion of the installation
ensure connections and back
case are not under any stress
due to misaligned pipework or
electrical cables.
Turn on the water supply
11
and check for leaks.
Strip back sufficient outer cable
12
insulation to enable routing to
terminal block.
13
Fit an earth sleeve to the earth
wire.
14
Loosen the screws in the terminal
block and insert the wires.
L
(Live) = Brown wire
(Protective Earth) =
Green /Yellow sleeved wire
N
(Neutral) = Blue wire
Tighten the screws in the terminal
15
block, ensure the wires are
secure and tight.
Inlet
Connector
Olive
Compression
Nut
Inlet Supply
Pipe
L
Terminal
Block
Electrical
Cables
Cold Water Supply
Pipe / Inlet Connector
15
N
Outlet
Connector
1494247-W2-A