Bluetooth Unpairing (Transformer)
Some spare part renewal e.g. control PCB, may require the shower and
pump to be unpaired and then paired again.
1
T u r n o f f t h e
electrical supply
to the shower.
Bluetooth Unpairing (Shower)
1
T u r n o f f t h e
electrical supply
to the shower.
Re-pair the transformer and the shower following the bluetooth pairing procedure.
1306246-W2-D
2
1 2 3 4 5 6 7
1 2 3 4 5 6 7
Leave the power to the pump
still on. The light will flash
blue.
2
OFF
ON
M o v e t h e B L E P U M P
ENABLE switch to the off
position.
3
10 30 60
1 2
10 30 60
1 2
Press the start button and hold
until the light flashes red again.
The pump is now unpaired.
After unpairing and if required,
follow procedure for bluetooth
pairing to pair.
BEAB CARE MODE
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE
Turn on the electrical supply
to the shower. The shower is
now unpaired.
26
1 2 3 4 5 6 7
1 2 3 4 5 6 7
3
10 30 60
1 2
10 30 60
1 2