Kohler K-1394 Series Manuel d'installation - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Kohler K-1394 Series. Kohler K-1394 Series 4 pages. Bath whirlpool

Kohler K-1394 Series Manuel d'installation
14-7/16"
11-5/16"
(36.7 cm)
(28.7 cm)
2-3/4" (7 cm)
3-1/2" (8.9 cm)
3" (7.6 cm)
Product Information
Whirlpool with chromatherapy
lights
Whirlpool w/o chromatherapy
lights
Required accessories:
Jet trim kit
Fixture:*
basin area
Bathing
54-1/2" (138.4 cm)
well
x 44" (111.8 cm)
water depth
To
19" (48.3 cm)
overflow
* Approximate measurements for comparison only.
Pump: (Qty. 2)
Hp
Variable speed
2 hp
Cut-out template
1022209-1-C
K-1394-H3
26-5/16"
(66.8 cm)
21-1/8" (53.7 cm)
66" D. (167.6 cm)
9/16" (1.4 cm)
2" O.D.
K-1394-H2
not
shown
K-1394-H3
shown
K-9398
top area
weight
61-5/8" (156.5 cm)
260 lbs.
x
(118 kg)
54-1/2" (138.4 cm)
capacity
196 gal. (742 L)
Voltage
Frequency
Amps
240 V
50/60 Hz
18 A
1006705-7
No change in measurements with drain
shown. (K-7167 or K-7167M)
Drop-in cut-out 64-1/2" D. (163.8 cm)
Note: Pump Protrusion Beyond Rim
3-1/2" (8.9 cm)
Pump/Control Access
48" (121.9 cm) W x
18" (45.7 cm) H Min.
2-1/2" (6.4 cm)
25"
23-1/2"
(63.5 cm)
(59.7 cm)
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB):
Pump/control
220-240 V, 20 A, 50/60 Hz
Heater
220-240 V, 20 A, 50/60 Hz
Installation Notes
NOTE: Pump protrusion beyond rim.
Install this product according to the installation guide.
Two separate 240 V electrical services required; one for the
pump/control, and another for the heater.
Floor support under whirlpool must provide for a minimum of
2500 lbs. (1134 kg).
Hot water supply should be 70% of capacity or greater.
Installations will vary.
2