Kohler Taboret Rite-Temp K-T8224-4 Manuel d'installation - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Kohler Taboret Rite-Temp K-T8224-4. Kohler Taboret Rite-Temp K-T8224-4 25 pages. Single-control bath and shower trim
Valve Stem
Discard plaster guard
with dome.
Setscrew
Skirt
Handle
Stem
Screw
Screws
Faceplate
Handle
O-Ring
Plug
Plug Button
4. Install the Faceplate and Handle
Remove and discard the plaster guard and/or dome, if installed.
Rotate the valve stem fully counterclockwise.
Position the handle stem over the valve stem with the eyelets
vertical. Secure with a screw.
Slide the skirt, with the O-ring installed, over the handle stem
and onto the valve.
Secure with a setscrew.
Slide the faceplate over the skirt. Secure with two screws.
Install an O-ring onto the plug.
Position the handle over the handle stem eyelets. Secure by
threading the plug into the handle.
Press the plug button firmly into place.
If needed, install the second O-ring, ring, and end piece.
Swirl and Square Handle
Kohler Co.
Valve Stem
O-Ring
Stem Extension
End
(Swirl Handle)
Piece
Ring
O-Ring
Faceplate
Plug
Bonnet
Plug
Adapter
Button
Swirl Handle
7
Discard plaster
guard with dome.
Stem Extension
(Square Handle)
Setscrew
Skirt
O-Ring
Screws
Screw
Square
Handle
1031365-2-B