K-1111-H2
22-1/2"
(57.2 cm)
11/16" (1.7 cm)
Product Information
Whirlpool
Fixture:*
basin area
Bathing
45" (114.3 cm) x
well
43" (109.2 cm)
water depth
To
19-1/2" (49.5 cm)
overflow
* Approximate measurements for comparison only.
Pump:
Heater
1.5 hp
1.5 kW
Required Electrical Service
Dedicated circuit required, protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB):
Pump/control
220-240 V, 20 A, 50/60 Hz
1042951-1-A
13-1/2" (34.3 cm)
69-1/4" (175.9 cm)
3-1/2"
(8.9 cm)
3" (7.6 cm)
K-1111-H2
shown
top area
57" (144.8 cm) x
57" (144.8 cm)
capacity
170 gal. (643.5 L)
Volts
Frequency
Amps
220/240 V
50/60 Hz
11 A
6-1/2" (16.5 cm)
17-3/8"
(44.1 cm)
No change in measurements with drain
40"
shown. (K-7167-AF or K-7167M-AF)
(101.6 cm)
4"
(10.2 cm)
Pump/Control Access
34" (86.4 cm) W x
15" (38.1 cm) H Min.
2-1/2"
(6.4 cm)
Notes
Install this product according to the installation guide.
Floor support under whirlpool must provide for a minimum of
2500 lbs. (1134 kg).
weight
Hot water supply should be 70% of capacity or greater.
Installations will vary.
300 lbs.
(136.08
An access panel for the pump/control is required. The minimum
kg)
dimension should be 34" (86.4 cm) wide by 15" (38.1 cm) high.
The drop-in cut-out dimension should be 68" (172.7 cm) by 68"
(172.7 cm).
If installing a rim mount faucet, make sure there is no interference
with drain overflow and circulating system before drilling any
holes. Consult local and national codes for minimum air gap
requirements if installing a spout on the faucet deck.
Fixture conforms to ANSI Standard Z124.1. All dimensions are
nominal.
2
Recommended faucet area.
69-1/4" (175.9 cm)
2" OD
24"
(61 cm)
Kohler Co.