. Power connection

DANGER: Risk of electrical shock. For plug-in installations/wall-mounted electrical supply: connect only to
a properly-grounded, grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI).
Do not remove the grounding pin or use a grounding adapter.
DANGER: Risk of electrical shock. For hardwire installations/through-floor electrical supply:
Connect only to a properly-grounded, dedicated 220V~, 50Hz, 10A circuit protected by a Class A Ground-Fault
Circuit-Interrupter (GFCI) or Earth-leakage Circuit-Breaker (ELCB).
Note: no extended wire is allowed.
Note: receptacle without grounding wire is not allowed. (Series with power cord) plug the power cord into receptacle.
NOTE: This product is designed for installation with the electrical supply attached to the wall. Both types are
illustrated.
Hard power cord installation shall comply with dimension drawing requirement.
Plug the power cord into receptacle.
If toilet power outlet direction modification is required. Adjust toilet power cord outlet when necessary as
following steps.
Push clamp 3 up as shown, remove power cord inside the slot.

. Power on and water on test

1. Turn on toilet water supply first, and then connect power supply when there's no water leak.
2. Make sure turn power switch on left side to ON position (button indicating LED ON), toilet start water and power
self-inspection, fill water tank. When hear one "Beep", night light is OFF, self-inspection completed and the toilet
is ready for use.
3. Confirm proper flush status.