Kohler GABRIELLE CLASS FIVE S-EB K-3322T-SW Manuel d'instructions d'installation
To elevate water level: Rotate screw
clockwise and raise float to the desired
water level. Elevate water cup to a
proper position as well. (Refer to float
adjustment instructions.)
Fasten the snap along "CLOSE"
direction.
Float adjustment instructions: Make
sure the height of surface E is 2-4mm
lower than surface G.
1176009-T01-A
Fig.#10c
10c
Fig.#10d
10d
Screw
E
Float
G
Water Cup
Fig.#10e
10e
-6-
CLOSE
E
G 2-4mm