Service
Precleaner
If so equipped,
wash and reoil the precleaner
every 25
hours of operation
(more often under
extremely
dusty
or dirty conditions).
Replace the precleaner
annually
or every 100 hours.
1. Open the door on the blower housing
to access
the air cleaner element
and precleaner.
See
Figures 10 and 11.
2.
Unhook the latch and remove tile precleaner
from
the air cleaner element, or remove as an assembly
for servicing.
Make sure the base and the sealing
area is clean before reassembly
is performed.
See
Figures 12 and 13.
.
Wash the precleaner
in warm water with
detergent.
Rinse the precleaner
thoroughly
until
all traces of detergent
are eliminated.
Squeeze out
excess water (do not wring). Allow the precleaner
to air dry.
4. Saturate
the precleaner
with new engine oil.
Squeeze out all excess oil.
5. Reinstall the precleaner
over the paper element
and secure with the latch.
6. Close and latch the door.
7. When precleaner
replacement
is necessary
order
genuine
Kohler Parts.
32 083 05-S Precleaner
37 mm (1.45 in.) high
32 083 08-S Precleaner (PRO)
71 mm (2.79 in.) high
Service
Paper
Element
Check the paper element
every 50 hours of operation,
(more often under extremely
dusty or dirty
conditions).
Clean or replace the element
as necessary.
Replace the air cleaner element
annually,
or every 100
hours.
1. Open the door on the blower housing
to access
the air cleaner element.
See Figures 9 and 10.
2. Unhook
the latch and remove the air cleaner
element
and precleaner
(if equipped).
See Figure
12 and 13.
3. Remove the precleaner
(if so equipped)
from the
paper element.
Service the precleaner
as described
in Precleaner
Service.
.
Gently tap the paper element
to dislodge
dirt. Do
not wash the paper element
or use pressurized
air, as this will damage the element. Replace a
dirty, bent, or damaged
element
with a genuine
Kohler part. Handle the new element
carefully;
do not use if the sealing surfaces are bent or
damaged.
32 083 03-S Element
44 mm (1.73 in.) high
32 083 06-S Element (PRO)
78 mm (3.07 in.) high
5. Clean the air cleaner base as required
and check
condition.
6. Reinstall the precleaner
(if equipped)
over the
paper air cleaner element
and install on the base.
Secure with the latch.
7. Close and latch the door.
Clean Air Intake/Cooling
Areas
To ensure proper
cooling, make sure tile grass screen,
cooling fins, and other external surfaces
of the engine
are kept clean at all times.
Every 100 hours of operation
(more often under
extremely
dusty, dirty conditions),
remove the blower
housing
and other cooling shrouds.
Clean tile cooling
fins and external surfaces as necessary.
Make sure the
cooling shrouds
are reinstalled.
10