acaia AP009 Manuel de l'utilisateur - Page 11

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} acaia AP009. acaia AP009 18 pages.

acaia AP009 Manuel de l'utilisateur
Sleep Timer Setting [ SLEEP ]
1. The default setting is 5 minutes.
2. The number displayed indicates the amount of time before the scale will automatically power
off. For example, when 10 is selected and the scale is disconnected from all mobile devices,
the scale will power off after 10 minutes of no use.
Brightness Setting [ bright ]
1. The default setting is 2.
2. You can adjust the brightness of the LED display. Set to 4 when operating under strong light,
such as when outdoors.
Battery Saving Setting [ bAttSAvE ]
1. The default setting is 90 seconds.
2. The scale will wait for the selected number of seconds to enter Battery Saving Mode.
The LED display will dim to save power.
Zero Tracking Setting [ trAcE ]
1. The default Zero Tracking is set to 2 d.
2. Zero Tracking is a function to help compensate the weight readout fluctuations at zero point
to improve the usability of the scale. Acaia Pearl is allowed to compensate fluctuations of up
to 3 d according to the industrial weighing guidelines.
3. Off: It is not recommended to turn off Zero Tracking as the zero indication can drift easily as
the room temperature changes.
4. 0.5 d~3 d : For example, since each division is 0.1 g, 3 d = 0.3 g. When Zero Tracking is set
to be 3 d, any initial weight between ± 0.3 g on the weighing pan would be zeroed out.
5. 2 d is recommended in general for Acaia Pearl.
Key Sound Setting [ bEEP ]
1. The default setting is On.
2. Use this setting to turn the beeping sound on or off.
Weighing Filter Setting [ FiLtEr ]
1. The default setting is Fast.
2. The weighing filter setting determines the speed with which the load receptor responds to
and determines the weight. "High" indicates a more stable but slower weighing result;
"Fast" indicates higher sensitivity and a faster weighing result.
Default Weighing Unit Setting [ Unit ]
1. The default unit is gram.
2. You can also switch the weighing unit by pressing and holding the Tare button while in
different brewing modes.
11