a-TroniX 9887579 Manuel d'installation et d'utilisation - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} a-TroniX 9887579. a-TroniX 9887579 16 pages. Mppt solar charge controller

a-TroniX 9887579 Manuel d'installation et d'utilisation
Machine Translated by Google
operation manual
MPPT solar charge controller X45/10

8.Bluetooth

The controller has a Bluetooth communication function. After successfully installing the app,
the controller can be connected to the mobile phone via Bluetooth.
For detailed instructions, please read the instructions in the Bluetooth app.
With the help of the app, you can set the parameters, including the devices and battery
parameters. The operating status of the control unit is also displayed in real time.
8.1 Charging voltage wet, gel, AGM battery
With the charging voltages wet, gel or AGM battery, you must set the parameters for boost,
equalization and float voltage via the app.
The following voltage parameters apply to 25°C/12V systems:
charge level
boost
equalizing charge
float voltage

8.2 Lithium charging voltage

You can set the overcharge protection and overcharge recovery voltage of the lithium
battery through the app. Overcharge Protection (CVT): 10.0-17.0V Overcharge
Recovery Voltage (CVR): 9.0-16.8V
Overcharge Recovery Voltage + 1.5V>Lithium
Overcharge Protection Voltage > Overcharge Recovery Voltage + 0.2V.
If the deviation is greater than 0.2V, the manufacturer assumes no liability for a
system malfunction caused by this.
02/2022
area of
charging voltage
14.0-14.8V
14.0-15.0V
13.0-14.5V
default
charging voltage
14.5V
14.8V
13.7V
page 9