Aqua Computer AQUASTREAM XT USB Manuel d'utilisation et d'installation - Page 15

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'installation pour {nom_de_la_catégorie} Aqua Computer AQUASTREAM XT USB. Aqua Computer AQUASTREAM XT USB 20 pages.
Également pour Aqua Computer AQUASTREAM XT USB : Manuel d'utilisation et de fonctionnement (16 pages)

Aqua Computer AQUASTREAM XT USB Manuel d'utilisation et d'installation
aqua
computer
AQUASTREAM XT
sources" tab in the chart configuration and select a data set to be exported. If no
data sources are available, you will have to configure the log settings as described
in the corresponding chapter of this manual. Select the time period to be exported
on the right side of the window and start the export process by clicking the "Export
data" button. Enter a file name and path in the following dialog window.

11.4. Automatic data export

11.4. Automatic data export
11.4. Automatic data export
11.4. Automatic data export
The automatic data export feature can be used to save data from the aquasuite
into an XML file on the hard disk or in the RAM („memory mapped file") in a regu-
lar time interval. The automatic data export will always overwrite the previously
saved data, so the file always contains only the most recent data set. Select "Auto-
matic data export" below the "Data log" headline in the listing to access the set-
tings screen. Create a new export data set by clicking the plus symbol in the upper
right corner of the screen. Enter name, path and time interval to meet your re-
quirements. You may then add the data sources to log by clicking the plus symbol
in the "Data sources" window section. You may add an unlimited number of data
sources to each export data set, the total number of export data sets is also unlim-
ited.

12. Pump configuration (aquasuite)

12. Pump configuration (aquasuite)
12. Pump configuration (aquasuite)
12. Pump configuration (aquasuite)
Select "Pump" from the device list for the device to be configured.

12.1. Pump mode

12.1. Pump mode
12.1. Pump mode
12.1. Pump mode
In the upper area, current pump data (speed, voltage, current) is displayed as
plain text as well as in a diagram.
Select the desired mode of operation below the diagram. If "Automatic maximum
pump speed" is selected, the pump will automatically operate at the highest ap-
plicable speed. The pump controller constantly monitors rotor orientation, electric-
al current, power dissipation and supply voltage to calculate optimum rotation
speed. During power up, the pump may fall back to standard speed several times
until the highest (stable) operating speed is determined. Using standard water
cooling setups, this speed will normally be around 4000 – 5000 rpm depending
on the resistance of the system. The maximum speed can be limited by changing
the parameter "maximum pump speed".
If "Manual speed settings" is selected, you can set the rotation speed of the pump
manually. If the selected speed cannot be attained, the pump controller will use
the highest stable rotation speed (below the set speed) just like in automatic mode.

12.2. Power settings

12.2. Power settings
12.2. Power settings
12.2. Power settings
In manual speed mode, set the desired pump speed.
© 2007-2013
Aqua Computer GmbH & Co. KG
- 15 -
Gelliehäuser Str. 1, 37130 Gleichen