Aqua Control AirPro 3 Manuel d'installation et d'utilisation - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Aqua Control AirPro 3. Aqua Control AirPro 3 6 pages. Lake bed aeration
Timer Setting (AirPro models only)
Remove the clear cover by pulling it straight out from the timer. Review the following instructions for proper operation.
There are three positions for the power switch:
Use timer settings mode
Maintenance and Troubleshooting
Keep the cabinet air inlets and outlets free of debris and weed growth for proper ventilation.
If the system does not power on:
Press and reset the GFCI electrical receptacle located inside the cabinet. For AirPro models with timers: if the compressor(s)
still won't turn on, check that the timer is set correctly. If the timer is correctly set and the compressor(s) still won't operate,
flip up the white manual override toggle located ner the center-right on the timer. If it still won't power on, contact your
distributor or the factory for further assistance.
Note: Before performing any of the following maintenance or troubleshooting, unplug the system from any power outlet.
If the size or appearance of the surface aeration has decreased from initial installation, perform on or more of the following:
Always on positon
The time switch is
set by pushing the
captive trippers to
the outer rings
position in (green)
the Lake Bed
Aerator will be
turned on for that
period. Each tripper
represents 15
minutes. When they
are on the inner
position the Lake
Bed Aerator will not
turn on during
these positions.
O position
Turn the minute hand (shown in red)
clockwise until the current time is aligned
with the triangle (shown in green) on the
inner dial. The hour and the minute dial
will show exactly the current time. Snap
the clear cover back onto the timer.
Lake Bed Aeration
Aqua Control, Inc. — 5