DRAIN INSTALLATION

NOTE: Pipe jointing is a trade skill and should be executed only by qualified persons. Aqua Cooler recommends
installing a union as part of the PVC drain assembly to enable ease of disconnection if the fountain requires
service.
1.
Make sure all connections are cleaned and dry.*
2.
Mark waste pipe at a distance equivalent to full depth once inserted into the drain fitting on the unit.
3.
Apply Watermark certificated Type N solvent cement on the end of the Watermarked AS/NZS 1260 40mm
PVC pipe and insert into the Aqua Cooler drain outlet fitting. Firstly to the inside of the M Series drain
fitting and then to the external surface of the pipe end (marked area). (See Figure.1) #
4.
Please ensure the solvent cement is applied in full even coats to all applicable surfaces.
5.
Follow the direction line in figure.1 to connect the PVC pipe to the full depth of the socket and hold the
bond joint in position for at least 30 seconds.
6.
Do not disturb for 5 minutes and allow 24 hours curing before testing. (See Figure.2)
* Aqua Cooler suggests using PVC priming fluid to prime PVC pipe prior to application of PCB pipe cement for
all installations.
#2: Using both pipe cement type N and type P are both acceptable. Pipe cement type P is recommended
in high pressure application for bonding, while type N is for the non-pressure application. Aqua Cooler
recommends using pipe cement type N complying with AS/NZS3879 for this application.
Please be aware that the connection should be done by an Australian certified plumber.
The socket is adaptable to Watermarked AS/NZS 1260 40mm PVC pipe fitting as per the WMTS105
documentation.