PREPARATION CONT.
Remove fountain nose assembly. Tool Needed: T20 Torx bit
Remove 4x #10 Torx screws from the fountain.
Disconnect ONLY the nose assembly wires from the cold control and solenoid valve. Leave
all other wires connected to the cold control and solenoid valve. For nonrefrigerated models,
unplug the unit.
Disconnect the water line from the bubbler inside the nose. DO NOT disconnect from the
fountain.
DO NOT REMOVE COLD CONTROL OR SOLENOID VALVE
ASSEMBLIES FROM THE FOUNTAIN.
After the nose assembly has been removed, cover the two bare terminals with
the insulated female spade terminals (provided) for safety.
NOTE: The image shown may differ from some
models but the instructions will still apply.
Your Partner in Cool.
6
PREPARATION CONT.
Locate the solenoid valve on the Elkay unit. Disconnect both water lines from the solenoid valve.
Join the two water lines together using a ¼" elbow fitting (provided) (Fig. 7A).
Allow the cooling tank water outlet line to extend freely upward (Fig. 7B).
7