Dexter Laundry T 30 C Series Dépannage, codes d'erreur et schémas
Symptom
Tumbler does not turn
Tumbler turns but no spark at burner
2
Part # 8533-076-001 11/13

Dryer Trouble Shooting

Probable Cause
Drive belts
Tumbler does not turn
Door switch
Timer Tumbler does not turn
Glass fuse
Thermostat
Ignition
Transformer
Over temperature
Ignition control
Air Flow Switch
Hi-limit
Gas supply
Suggested Remedy
Check both drive belts. Replace if failed.
Check capacitor and motor. Replace if failed
Check door switch contacts and adjustment.
Adjust or replace door switch.
Check to see if heat timer is turned on
Check small glass control fuse in back of
dryer. Replace if failed.
Check if voltage is passing through the
two wires attached to the temoprature
thermostat
Check for 24VAC output from transformer.
Replace if have 120V between black & white
and no 24V between red and yellow.
Check to see if manually resettable
thermostat. Thermostat is kicked out. Reset
by pushing red reset button.
Check for 24VAC coming into the control
on the at burner red wire. If voltage, then
check for 24VAC out on the brown wire. Also
check for spark at the ignitor. If no 24VAC
output or no spark to the ignitor, replace
ignition control.
Check air flow switch to be sure it closes
when dryer is running. If not, adjust or
replace switch.
Check for continuity. Should be 0 ohms
resistance when cold. If not, replace
thermostat.
No gas can cause system lockout