Symptom
Probable Cause
Tumbler turns,
Gas supply
ignition sparks, no
fl ame
Gas pressure
Spark Electrode Sensor
Gas valve
Ignition Control
Burner Lights, but
Electrodes
goes on and off
Slow drying
Temperature Setting
Air fl ow restrictions necessary 1. Check lint screen and clean if necessary.
Temperature Sensor
Suggested Remedy
Make sure gas supply is working.
Make manometer check of gas pressure. Adjust if
necessary.
Check for damage to electrode or mounting.
Replace if necessary.
Check coil continuity, replace valve if failed.
Check for 24VAC to gas valve coils. If no voltage
replace ignition control.
Check low voltage harness for possible wire break
or cuts to allow no signal back to ignition control
Check program for correct high temperature
setting. Adjust if necessary.
2. Check exhaust for correct length and clean if
necessary.
3. Check exhaust damper to insure that it opens
when dryer is running and closes when dryer is
not in use.
4. Check makeup air to insure that it is adequate.
Increase makeup air if necessary.
5. Check static Back pressure no more than .3
The temperature sensor should have between
30,000 ohms and 60,000 ohms resistance at room
temperature if okay. Replace if not in this range.
5
Part # 8533-066-001 2/10