A.H. Systems SAS-512-2 Manuel d'utilisation - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} A.H. Systems SAS-512-2. A.H. Systems SAS-512-2 14 pages. Log periodic antenna

A.H. Systems SAS-512-2 Manuel d'utilisation
A.H. Systems SAS-512-2 Log Periodic Antenna
EMISSIONS TESTING MEASUREMENT POINT:
For 3 and 10 meter testing, the measurement is made from the center of the
antenna radiating elements and is annotated by a measurement point sticker
(per ANSI C63.5).
IMMUNITY TESTING MEASUREMENT POINT:
Measurement is made from the tip of the antenna and typically preformed at a 1
meter distance. (3 meters per IEC 61000-4-3)
 A.H. Systems inc. – May 2014
REV C
7