AVM OVATION PA8 Manuel d'utilisation - Page 18
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} AVM OVATION PA8. AVM OVATION PA8 18 pages. Modular preamplifier
PA8, setting of phono card
To ensure that the phono card works in an optimal way, it must be set according to the requirements of the
cartridge. Please refer to the operating manual / technical data of your cartridge to find out the correct
settings. The setting is done by switches on the pcb. The upper switches are for the left channel, the lower
for the right channel. The switches for both channels must be set identically. You can set: sensitivity,
cartridge (MM or MC) and cartridge load. For fine tuning of sensitivitiy see additionally the level function of
the PA8 (see 3.4.1 Setting of input sensitivity).
MM-cartridges
Output voltage
Load capacitance
MC-cartridges
Output voltage
Load resistance
Please refer also to manual PA8 "2.4.1 Automatic software update"
S1/1 S1/2 S2/1 S2/2 S3/1 S3/2
< 1 mV
1 mV – 2,5 mV
2,5 mV - 5 mV
> 5 mV
up to 200 pF
OFF OFF OFF OFF
200 - 350 pF
OFF OFF
350 - 450 pF
OFF OFF OFF
450 - 600 pF
OFF OFF
S1/1 S1/2 S2/1 S2/2 S3/1 S3/2
< 100 µV
100 µV - 250 µV
250 µV - 500 µV
> 500 µV
25 - 75 Ohm
ON
75 - 150 Ohm
ON
150 - 500 Ohm
OFF
> 500 Ohm
OFF OFF OFF OFF
OFF OFF OFF
ON
OFF
ON
ON
ON
ON
ON
OFF OFF
OFF OFF OFF
ON
OFF OFF
18
S4
S5/1 S5/2
1+2
OFF OFF
ON
OFF
OFF
ON
ON
ON
S4
S5/1 S5/2
1+2
ON
ON
OFF OFF
ON
OFF
OFF
ON
ON
ON