Dexton C-11-213031 Manuel d'utilisation - Page 12
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Dexton C-11-213031. Dexton C-11-213031 20 pages. Ph regulator
2.6. Alarms and displays
LED / Status
flashing
flashing
switched on
switched on
switched on
switched on
flashing
flashing
attempts to correct
+
flashing
Daily injection time
of pH corrector
equal to or greater
than 2H (3,6L)
Meaning
Immediate action
pH < 6.6
pH regulation stopped
pH regulation stopped
pH < 8
corrector selected is
set at 7.0 (acid)
Series of
unsuccessful
the pH
OR
pH regulation stopped
Manually measure the pH using a recent testing
kit.
Manually measure the pH using a recent testing
kit.
only if
the type of pH
-
-
-
Operations to carry out
If the value obtained is close to 6.6 :
a) Switch off the electronics unit.
b) Pour basic pH corrector (pH+) into the
pool near the flow out nozzles to obtain a
pH of about 7.2.
c) Wait 30 minutes.
d) Switch the electronics unit on again.
e) Check that the pH measured by the
electronics unit is approximately 7.2.
If the value obtained is far from 6.6 :
Carry out a calibration of the pH probe.
If the value obtained is close to 8 :
a) Switch off the electronics unit.
b) Pour acid pH corrector (pH+) into the pool
near the flow out nozzles to obtain a pH
of about 7.2.
c) Wait 30 minutes.
d) Switch the electronics unit on again.
e) Check that the pH measured by the
electronics unit is approximately 7.2.
If the value obtained is far from 8 :
Carry out a calibration of the pH probe.
Ensure the pH corrector container is not
empty.
Check the condition of the filter with ballast
and injection connector.
Carry out a calibration of the pH probe.
6