Aqua Flo AQUV AQUV-8R12 Manuel du propriétaire - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Aqua Flo AQUV AQUV-8R12. Aqua Flo AQUV AQUV-8R12 16 pages. Ultraviolet disinfection system
(G) OPERATION AND MAINTENANCE
Your UV system is ON continuously during normal use and will continuously supply safe water. (Note: Do not try to shut it off during short periods of
non-use as repeated ON/OFF cycles can shorten the UV lamp and ballast life). Failure to follow disinfection procedure if the system is shut off could
result in micro-biologically unsafe water leading to potential illness or death.
To maintain the optimum disinfection performance of the UV system:
UV lamp should be replaced when the display reaches "0". At this point, the UV lamp continues to light but its ability to disinfect the water drops
below safe limits. Therefore the UV lamp MUST BE REPLACED WHEN THE LAMP REPLACEMENT ALARM "A3" COMES ON.
The quartz dome should be cleaned at the time of lamp replacement. If the water quality parameters listed in section 'C' are exceeded, you
should clean and inspect the quartz dome more frequently and clean as necessary.
Replace pre-filters every 4-6 months.
ITEM
UV Lamp
Quartz Dome
O-Rings
Carbon Filter
Sediment
Pre-Filter
Use only GENUINE AQUA FLO AQUV UV Lamps with your UV system. Aqua Flo UV lamps are designed
with extensive product research and engineering to provide reliable and consistent UV output and
performance that ensures the safety of your drinking water. Using non-Aqua Flo AQUV UV lamps can
not only compromise the system performance but also voids your product warranty, electrical and CSA
•
Unsafe drinking water which may lead to illness and/or death
Use of non-Aqua Flo AQUV lamps will void all warranty & product certification
Aqua Flo logo & lamp part #
CHANGING FILTER CARTRIDGES & REPLACING O-RINGS:
1. Shut off the inlet valve and open a faucet close by until pressure in the unit is relieved. Alternatively you can press the vent button on top of
the unit until pressure is released.
2. Place an empty bucket under the sump to catch any water spilling out of the housings.
3. Using the supplied wrench, unscrew the sump. Discard old cartridge and rinse sump.
4. Remove O-rings and replace if they have been in use for a year. Otherwise wipe them with a soft cloth or paper towel and clean the groove on
which the O-rings are seated.
5. Apply food-grade silicone lube on the O-rings and replace.
6. Clean inside of the head as well to make sure the sealing surface is free of debris
and stains.
7. Insert new cartridge into the sump and screw sump back on to filter. Hand-tighten
only. Slowly open the water and flush for a few minutes before use.
REPLACEMENT FREQUENCY
Every 1 year of use
Every 3 years
Annually
Every 1 year of use
6 months or when pressure across
the unit drops by 10psi
USE ONLY GENUINE AQUA FLO AQUV LAMPS
certification, and may result in any one or more of the following issues:
Genuine Aqua Flo AQUV lamps can be identified as follows:
CLEANING
N/A
At least during every annual lamp change. More
frequently if water is hard or has iron, manganese etc.
N/A
N/A
N/A
WARNING
•
Ballast failure
DO NOT USE WRENCH TO TIGHTEN SUMP.
•
Electrical fire
Blue ends
11
CAUTION!