Problem
Excessive
Water pressure is too high.
condensation in
Food Compartment.
Programming and or SHOT and Intr
values were adjusted improperly
(Timer Models only).
Excessive Steam
Worn or damaged Bun Caps.
escapes from front
or sides of steamer.
Steam Generator's
Water Pressure Regulator is faulty or
surface becomes
not properly installed.
flooded (fills with
Programming and/or the SHO value
excess water).
was adjusted or changed improperly.
Solenoid Valve is leaking due to
debris trapped inside the plunger.
Improper Daily/Monthly cleaning.
The Generator surface temperature
is too low.
Insufficient or excessive calcium/
mineral deposits on the Generator
surface.
Solenoid Valve is installed incorrectly. If the Solenoid Valve was replaced, verify that the
P/N 1011073 Rev. H 12/13
McDonald's
TROUBLESHOOTING (continued)
Possible Cause
SURFACE STEAMER SS-400TT
Corrective Action
Verify that the Water Pressure Regulator is set to
10 psi. Adjust accordingly.
Reprogram the SHO and H2O values as described
in the Programming section of this manual to factory
settings. See "Factory Resets."
Replace Bun Caps.
Verify that a Water Pressure Regulator is installed
and set to 10 psi. Adjust accordingly or replace.
Reprogram the Control Board to the recommended
settings. Refer to the Programing section of this
manual. See "Factory Resets."
Attempt to flush the debris out of the valve by
operating the unit on a number of cycles and then
letting it rest. If the unit still leaks, disassemble
the Solenoid Valve and clean out the plunger.
Reassemble the unit and test again. If a leak is still
present, replace the Solenoid Valves. Contact your
maintenance person or Authorized Service Agency.
Follow the Daily/Monthly cleaning procedures
carefully.
Verify that the Generator set point temperature is
between 400°F (204°C). See "Factory Resets."
Verify that a thin layer of calcium/mineral deposits
is present on the Generator surface. Refer to the
Maintenance section of this manual.
"IN" and "OUT" labels on the valve correspond to
the water flow.