- Fit the input and output connecting pieces (G) and connect the device to the input and output
paths. The water will enter via the static mixer and leave the device again via the UV-C/ozone
housing.
- Turn on the pump and check the system for flow and for leaks.
- Turn on the UV-C unit and the air pump.
Disassembly / Maintenance
In the event of maintenance or disassembly of the equipment always disconnect the electrical
power!!
- Switch off the power supply for the air pump, ozone device and the pond pump.
- The cover nut (H) must be undone at the top from the ozone device to replace the lamp (F).
Then carefully lift the lamp (F) a little. Undo the lamp (F) from the lamp base and replace it if
necessary. Refasten everything again carefully in the original position.
- The quartz glass (I) should be cleaned about once per year depending on the hardness of the
water and the pollution. To do this pull the glass carefully out of the housing using the pulling
piece (J). Clean the quartz glass using a suitable agent. Use a soft cloth to clean the glass and
avoid scratches.
- Do not touch the lamp (F) with your hands; use a soft cloth to hold the lamp (F). If the lamp (F)
is touched then it is advisable to clean it with a soft cloth and a little alcohol.
- Once all the parts have been put back in their original positions then the pond pump can be
started. Check the system for flow and for leaks.
- Turn on the air pump and the UV-C unit.
Guarantee conditions
The product is guaranteed against manufacturing faults for 2 years from the date of purchase. The
lamp is subject to wear. It should always be replaced in the Spring. The lamp and the quartz glass
are not guaranteed against breakage. Guarantee claims can only be handled if the product is
returned post-paid and providing a valid proof of purchase is included. Guarantee claims which are
caused by installation or operating faults will not be recognised. Defects arising from lack of
maintenance do not fall under the guarantee. Guarantee repairs may only be carried out by the
supplier. The supplier can not be held liable for consequential damage arising from failure, faulty
maintenance or incorrect use of equipment. The guarantee will lapse if extra facilities are added to
the product or if changes are made to the product which are not part of the standard equipment
(for example the use of 'third-party' connectors, cutting off the plug or the drilling of extra holes).
Technical data
UV-C (W)
Ozone
UV-C Ozone lamp
Pond capacity
Max pump
Max pressure
Parts
Quartz glass
Air pump
Lamp
Static Mixer
Solvent socket 63mm
Air hose
Adaptor 63-50
Nut for 3-part coupling
Adaptor 50 x 1.5" screw thread
Non-return valve
Adaptor socket 1.5"x 40-32-25
: 25Watts
: 0.6 gram
: 36 T5 HO VH 75W 4P-SE-BY1
: 10 till 50 m³
: 20,000 l/h