DeZurik G12 Instruction - Page 4
Parcourez en ligne ou téléchargez le pdf Instruction pour {nom_de_la_catégorie} DeZurik G12. DeZurik G12 19 pages. Cylinder operated actuator used on pec eccentric valves
Également pour DeZurik G12 : Manuel (14 pages)
DeZURIK
Cylinder Operated G-Series Actuator
Description
The G-Series Cylinder Actuator is a totally enclosed, quarter turn, pneumatic operated actuator. A 2"
(50mm) square nut on top of the actuator is provided for manual operation. It is supplied with a single
cylinder, and single or double booster cylinders dependent on application.
Air Supply
The supply pressure to the cylinder should be between 50 and 100 psi (344 and 689 kPa).
Lubrication
The G-Series Cylinder Actuator has been lubricated at the factory and requires no routine lubrication. If the
actuator is disassembled, lubricate the rack, rack guide, gear sector and bearings using one of these lubricants:
- Keystone Zeniplex-1 (recommended)
- Amoco Amolith Grease #1-EP (alternate)
- Amsoil GHD (alternate)
- Mobil Mobilux EP 1 (alternate)
- Petro-Canada Vultrex MPG EP 1 (alternate)
- Shell Alvania EP 1 (alternate)
- Texaco Multifak EP 1 (alternate)
If the cylinder is disassembled, it must be lubricated as described in the cylinder instructions.
Actuator Identification
The G-Series Cylinder Actuator is available in three sizes: G6, G12 and G16. See Figure 1 for actuator
identification.
To determine the actuator size, measure the diameter of the cover - see Figure 1 and Table A. To
determine the cylinder size, measure the diameter of the cylinder - see Figure 1 and Table B.
Table A: Actuator Identification
Actuator
G6
G12
G16
D10022
Figure 1 - Actuator Identification
∅ "A"
IN
MM
8
205
15
390
19
485
Page 4
Table B: Cylinder Identification
∅ "B"
Cylinder
IN
C4
4.5
C6
6.5
C8
8.5
C10
10.5
C12
12.5
MM
115
165
215
265
320
August 2012