10
LUBRICANT / CLEANER
Cristo-Lube MCG 111
Oakite #31
NETALU
Diluted white vinegar
Washing-up liquid (diluted with hot water)
Table 3. Recommended cleaners and lubricants
All O-rings
Attention: Silicone parts do not require lubrication. Do not grease them. Greasing silicone
parts can change their molecular construction and cause premature degradation of the material.
Acid bath for cleaning brass and stainless
steel parts.
Acid bath for cleaning brass and stainless
steel parts.
Acid bath for cleaning brass and stainless
steel parts.
Attention: Do not use hydrochloric acid for cleaning parts. Hydrochloric acid, even when well
diluted, attacks the coating of metal parts and leaves a corrosive deposit that damages plastic
parts and O-rings.
Degreases brass and stainless steel parts;
general cleaning of plastic and rubber
parts.
APPLICATION
Mistral Mouthpiece Service Manual
SOURCE
Aqualung, ref. 480025
Oakite Products, Inc.
Aqualung, ref. 455001
Household stores
Household stores