Aqua Lung Mistral Mouthpiece Manuel d'entretien - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Aqua Lung Mistral Mouthpiece. Aqua Lung Mistral Mouthpiece 14 pages.
Également pour Aqua Lung Mistral Mouthpiece : Manuel de maintenance technique (14 pages)

Aqua Lung Mistral Mouthpiece Manuel d'entretien
4
5.
Numbers in brackets indicate the part number of the
component shown on the exploded view attached.

DISASSEMBLY PROCEDURE

Note: Before commencing disassembly, consult
the exploded view to check the reference
numbers of all parts requiring replacement.
These parts should all be replaced by new parts
and should not be re-used on the pretext that
the regulator has seen little use since its
manufacture or since its last service.
Attention: Use only the special tool when
removing O-rings in order to avoid damaging the
seal recess. The slightest scratch on a sealing
surface could cause a leak. If a surface should be
damaged then this part should be replaced with a
new one. Do not use any pointed instrument or
metal tool to remove O-rings.
Mistral Mouthpiece Service Manual
1.
Cut the two tightening collars at the mouthpiece level
and remove the corrugated hoses from the connectors.
2.
Unscrew the screw connectors by hand.
3.
Remove the two connectors from the mouthpiece body.
4.
Remove the O-rings from the connectors.
5.
Remove the lip guard.
6.
Remove the mouthpiece clip (8) by lifting the cam with
your thumb, then remove the mouthpiece.