2.4 Optional Electrical Connections
1. CAL A/B (Dual Calibration)
Dual Calibration allows two calibration settings. To operate the TA1 amplifier in the
Calibration A configuration the connection to PIN 6 must be left open.
To operate the TA1 in the Calibration B configuration the 24V must be applied to PIN
6. A switch can be used as shown below. If a PLC or alternate source for 24V is
utilized be sure that the source has a common Ground with PIN 1. If you do not need
dual calibration no connection needs to be made to PIN 6.
FIGURE 7 - Cal A/B Electrical Connections
(See Appendix A for full Electrical Connections)
2. Remote Calibrate and Zero
FIGURE 8 - Remote Calibration and Zero Connections
(See Appendix A for full Electrical Connections)
5