Bilanciai PS440 Series Consignes de sécurité - Page 10
Parcourez en ligne ou téléchargez le pdf Consignes de sécurité pour {nom_de_la_catégorie} Bilanciai PS440 Series. Bilanciai PS440 Series 14 pages. For weighing terminals
5.1.1
Exe Connections
Terminal N° Signal
L
Line
T
Ground
N
Neutral
5.1.2
Exi Connections
Terminal N° Signal
1
OUT1
2
COM1
3
OUT2
4
COM2
5
OUT3
6
COM3
9
GND_RELAY
11
C-Out3
12
C-Out2
13
C-Out1
14
EXC-_EX
15
EXC+_EX
16
DGND
17
+14INPUT_EX
18
+6V_EX
19
+6VDISP_EX
5.1.3
Conductor connections
Prepare conductors with insulated pins for connection to the terminals.
Keep the exi conductors separate from the non-exi ones.
Description
Power supply: line
Safety ground connection
Power supply: neutral
Description
Output 1
Common 1
Output 2
Common 2
Output 3
Common 3
Common relay command
Output 3 command
Output 2 command
Output 1 command
exi - load cell power supply
exi + load cell power supply
Digital ground
exi power supply of the inputs and of the
board 4-20 mA analog current output
exi power supply for CPU
exi power supply for display
8