aqua metro Contoil DFM 12ECO Instructions de montage et d'utilisation - Page 12

Parcourez en ligne ou téléchargez le pdf Instructions de montage et d'utilisation pour {nom_de_la_catégorie} aqua metro Contoil DFM 12ECO. aqua metro Contoil DFM 12ECO 20 pages.

Electrical connections and specifications

Explanation of the wires

Wire colours
Function
Green
Signal 1 (SL)
Brown
Minus
White
Signal 2 (RL)

Specification and Technical Data

Switching element
Switching voltage
Switching current
Standby current
Switching power
Open-time
Operating temperature
Protection class
Consumption type
Fluids
Qmin / Qmax
Accuracy
Allowed pressure
Protection class
Signal output
Filter (mash size)
Temperature
Dimensions (l x h x w)
Weight
12
Remark
Signal is given when the contact closes. The external
device must bring the voltage, which will be redirected
over the "cable minus" to the external device.
Ground
Signal is given when the contact closes. The external
device must bring the voltage, which will be redirected
over the "cable minus" to the external device.
Reed switch with dry contact (inert gas)
Max. 48 VAC / VDC, Protection class III (SELV)
Max. 50 mA (Ri=47Ω / 0.5 W)
Not available (galvanic isolated)
Max. 2 W
50 % ±10 %
-20 °C to +80 °C
IP 66
Differential consumption measurement
Diesel fuel
10 l/h / 600 l/h
Better than 1 %
16 bar (operation pressure is viscosity depending)
IP 66
80 pulse/liters
The same mash size as the vehicle needs, at least 0.100 mm
Operating temp.
-20 °C up to +80 °C
Storage temp.
-40 °C up to +125 °C
157 x 96 x 81 mm
1.6 kg
Functions scheme
Supply/Return Line
+/–
Ri 47 Ohm
+/–
5.65078.4
®
CONTOIL
DFM 12ECO