Avonic CM55-VCUC Manuels d'utilisation - Page 5
Parcourez en ligne ou téléchargez le pdf Manuels d'utilisation pour {nom_de_la_catégorie} Avonic CM55-VCUC. Avonic CM55-VCUC 17 pages. Usb 2.0 compressed hd ptz camera
5 USB2.0 Interface
6 RS-232IN/IR Interface
7 RS-232OUT/RS-485 Interface
8 Power Input Interface (DC12V)
Bottom Part
9 Locating Hole
Used to define installation direction of the camera.
10 Installation Hole
1/4" inch screw, used to fix the camera.
11 DIP Switch
Used to set address, protocol, baud rate and other
parameters.
DIP Switch Setting
Before operating the camera, please set camera's
address, baud rate protocol and etc. through its DIP switch
located at the bottom part of the camera. There are two
switches named SW1 and SW2.
Note
The SW1 and SW2 switches look the same, their settings
are different. SW1 is used to set camera's address and
mounting types, while SW2 is used to set camera's control
protocol and baud rate.
Default Settings
Camera Address
Baud Rate
9600bps
Protocol
Mounting Type
www.avonic.eu
1
VISCA
Stand
5
SW1 Settings
Use DIP1 to DIP6 to set 64 address accordingly. DIP7 is
reserved. DIP8 is used to set camera's mounting type.
Please refer to Annex 3 for detailed SW1 definitions.
SW2 Settings
Use SW2 to set camera's protocol, baud rate. Use DIP1
and DIP2 to set camera's protocol, use DIP 3 and DIP4 to
set camera's baud rate. DIP5~DIP8 switches are reserved.
SW2
DIP No.
1
2
OFF
OFF
ON
OFF
Protocol
OFF
ON
ON
ON
DIP No.
3
4
OFF
OFF
ON
OFF
Baud
Rate
OFF
ON
ON
ON
Note
It requires a reboot of the PTZ for the switch setting to take
effect.
Remote Control
VISCA
PELCO- D
PELCO- P
-
2400
4800
9600
38400