Installation requirements.

XL, XT, XR.
Components for Billi Quadra Compact,
420, 440, 460, 4100 & 4180 Models
Before commencing installation,
ensure you have identified the following.
1. Underbench module
2. Dispenser upper with tubing
3. Dispenser base & mount
4. Barb locking bush
5. 4mm chrome screw & allen key
6. Large washer
7. Tube spring clamps x 3
8. 600mm flexible braided hose
9. Drain fittings (water-cooled only)
including John guest fittings
10. 3/8 tube connected with adapter
to 3/16 black tube
11. ½ inch drill bit (not included)
12. Behind door panel:
a. filter cartridge
b. user guide
c. warranty registration card
13. Ensure a Stop Tap is installed 600mm
from the Billi unit water supply inlet
(Stop Tap not supplied)
Additional Components – XR
14. Remote panel kit
Determine Unit Location
Plan the installation. Dispenser tube lengths,
position of power and water outlets, required
air space around the underbench module and
access for service must be considered before
cutting tube lengths. Refer to Diagrams 1 and
2 and the table below for clearances around
unit. Unit must be installed horizontally with
display panel facing to front of cupboard.
The Quadra is designed for internal
installation only.
Model
Height
Quadra Compact
340mm 315mm 365mm
Water cooled
Quadra Compact
340mm 315mm 410mm
Air Cooled
Quadra 400 models/
340mm 315mm 465mm
Quadra Plus Water cooled
Quadra 400 models/
340mm 315mm 510mm
Quadra Plus Air Cooled
Water Supply
The Quadra must only be connected to a cold
water supply. A ½" BSP stop tap (not supplied)
is to be installed in an easily accessible
position within 600mm from the Quadra
water supply inlet. The Quadra incorporates
a certified pressure limiting and backflow
prevention device. Do not fit an additional
pressure limiting valve.
Dynamic water supply pressure:
Min. 250kPa, max. 500kPa*.
Supply temp: min. 5°C, max. 30°C.
* Where supply pressure is greater than
500kPa PLV must be fitted. Billi recommends
PLVs with anti-hammer properties.
2
Do not install with water that is
microbiologically unsafe or with water of
unknown quality without adequate disinfection
before or after the system. Systems certified
for cyst reduction may be used on disinfected
water that may contain filterable cysts.
Power Requirements
A single 3 pin GPO is required. A dedicated
circuit should be provided and must be fitted
with an earth leakage protection device (RCD).
An externally fitted RCD device is acceptable.
Quadra Compact 420, 440, 460, Plus 5 and
Plus 9 require a 10 amp rating.
Quadra 4100 and Plus 15 require a 15 amp
rating.
Quadra 4180 requires a 20 amp rating.
All Quadra models are supplied with a 1
metre flex cord and plug.
Drainage
Water-cooled Quadra models require a
drainage point such as a dishwasher nipple.
Use the nipple adaptor fitting supplied or the
clamp-on drain adaptor (both supplied with
system). Clamp-on drain adaptor must be
installed above the water seal on the sink
side of the water trap.
Ventilation
Required for Air-cooled Models only
Air-cooled Quadra models require
cupboard ventilation, adequate air space
and an unobstructed clearance of at least
25mm on each side of the underbench
unit. Door ventilation is to be provided in
the bottom and top of the cupboard door
(Diagram 3). Suitable vent grills are available
from Billi Pty Ltd (Part no: 985050). For high
usage installations, an optional low voltage
door fan kit is available and should be fitted
Width
Depth
if cupboard internal temperatures exceed
35°C (Billi Part no: 990713).
Tubing
Power
removed
Outlet
for clarity
800mm
Tube Length
Supplied
Stop Tap
(Installed by
Plumber)
20mm
175mm
205mm
10mm
bench
thickness
1mm-48mm
35mm
70mm
Tubing
removed
for clarity
Air-cooled Models only
100mm
vent grilles
100mm
150mm
Min.
Clearance
Diagram 1
130mm
Diagram 2
120mm
optional
door fan
Diagram 3