Electrical
A Ground Fault Circuit Interrupter (GFCI) is required in the circuit. For size of GFCI required see the GFCI manufacturer's instructions.
• Never ground to a gas supply line.
• To avoid dangerous or fatal electrical shock turn the pump OFF, disconnect the power at its source, lock out power to motor, and place a
tag on the dedicated GFCI circuit breaker indicating the power is to remain OFF before working on electrical connections.
Ground Fault Circuit Interrupter (GFCI) tripping indicates an electrical problem. If GFCI trips, determine the reason for tripping. If you are
uncertain, have a qualified electrician inspect and repair the electrical system. Verify that the supply voltage matches the nameplate
voltage. Incorrect voltage can cause fire or seriously damage the motor and voids the warranty.
VOLTAGE & CHANGING DEFAULT SETTING
Voltage at the motor must be within 10% of the motor nameplate rated voltage or the motor may overheat, causing overload tripping and
reduced component life. Verify voltage is correct before applying power. If voltage does not fall within the specified range during operation
consult the power company.
DV FLO pump is factory wired for 230 volt operation. This pump can also be used with 115 volt. Please refer to the wiring diagram and use
the supplied electrical components (located in filter basket of new pump) to change from 230 volt factory setting to 115 volt operation.
Figure 5 - DV FLO Pump Wiring Diagram