Aqua Science Fleck 5600 SXT Manuel d'installation - Page 6

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Aqua Science Fleck 5600 SXT. Aqua Science Fleck 5600 SXT 12 pages. Digital water softener system

Fleck 5600 SXT Digital Water Softener System Installation Manual
Brine Tank Assembly
Insert the Salt Grid Base you just assembled into the Brine Tank. Make
sure that the hole in the Float Tube lines up with the hole in the Brine Tank.
NOTE: You will need to remove the Float Assembly to properly adjust
Remove the Nut from the top of the Float Assembly and set aside.
Watch for a small Plastic Insert that's hiding behind the Nut. You'll
need to insert it into the Brine Hose. It's a good idea to do this
right away so this small piece doesn't get lost.
Adjust the rubber grommet on the Float Assembly to about 12 to 16 inches from the bottom of the Assembly.
Bottom
Make sure all connections are hand tight. Be sure not to over tighten or use tools. It could damage the threads.
800-767-8731
Snap the (4) Legs into the Salt Grid Base. Then insert the Float Tube into the Salt Grid
Base. Push it through until it touches the ground.
Make sure that the hole in the Float Tube is facing straight outward (See next step).
12" - 16"
6
Note: Make sure push that Plastic
Insert all the way into the Brine Hose.
www.aquascience.net
Top