QUICK START GUIDE
Your pump was assembled and wired and then programmed and test before shipping. It should
be ready for you to use without any modifications or changes required on your part. DO NOT
MAKE ANY PROGRAMMING CHANGES WITH OUT CONTACTING THE FACTORY FIRST.
FAILURE TO DO SO WILL VOID THE WARRANTY.
1) Connect the inlet (suction) line to the Tri-clamp fitting on the front of the pump using a new
Tri- Clamp gasket and a heavy duty clamp. The inlet line should be at least the same diameter as
the fitting on the pump and care should be taken to avoid putting a valve or a tee immediately
before the pump.
2) Connect the discharger line to the Tri-clamp fitting on the top of the pump using a new Tri-
clamp gasket and a heavy duty clamp.
3) Plug the power cord in to an appropriate wall receptacle. THE PLUG SHIPPED ON YOUR
PUMP MATCHES THE VOLTAGE SETTING ON THE CONTROLLER. DO NOT CHANGE THE
PLUG OR USE AN ADAPTER, THIS WILL VOID THE WARRANTY.
4) Open the valve on inlet line to the pump to allow liquid to flow to the pump
5) Open the valve on the discharge line if you have one installed
6) Adjust the Potentiometer (speed control knob) on the front of the digital pump controller
to the midpoint so that the indicator dot on the knob is at the top.
7) Press the RUN/STOP button briefly to start the pump
8) Adjust the speed of the pump by using the Potentiometer to obtain your desired flow.
9) If the OL LED (overload) is lit then slow the pump down or restrict the discharge flow until
the OL LED goes off.
10) When you are finished pumping stop the pump by pressing the RUN/STOP button. The
STOP LED will illuminate. DONOTSTOPTHEPUMPSIMPLYBYTURNINGDOWNTHEPOTEN-
TIOMETER TO ZERO. THIS WILL STILL ALLOW VOTAGE TO THE MOTOR AND CAN
CAUSE DAMAGE AND ELECTRICAL SHOCK.
11) Close both the inlet and discharge valves if equipped.
NOTE: Do not try to run your centrifugal pump in reverse. It will not operate in reverse so the
FWD/REV switch has been disabled.
Page 1