regular maintenance
The R900 bill validator will not need to be cleaned as often as magnetic sensing bill acceptors.
However, if it becomes too dirty, that will effect to product performance such as bill acceptance rate, etc.
To maintain the bill validator with the best performance, we recommend to do regular maintenance once every 3-6 months.
If cleaning is required, use a soft cloth moisture with mild non-abrasive detergent.
Cleaning Mode
Use proper cleaning sheet CPI supported. (Contact local ASC)
To enter the "Cleaning Mode", press the push switch twice
The bezel lam starts flashing. It means the product is in "Cleaning Mode"
To cancel the "Cleaning Mode", press push switch once or leave it for 30 seconds
Insert the cleaning sheet into the bill insertion slot.
The sheet is pulled inside to start the cleaning operation.
The sheet moves back and force 3 times to complete bill path and sensor cleaning.
Upon the completion of cleaning, the cleaning sheet is returned to the bill insertion slot.
To enter the "Cleaning Mode"
To enter the "Cleaning Mode"
Phase2 - R900 Installation Guide (V1.1 2020-04-16).docx
Press push switch twice
keeps Flashing
Insert cleaning sheet
into bill insertion slot
If the BV is in "Cleaning Mode",
the bezel lamp starts flashing
Bezel Lamp
Once completed cleaning for
bill path and validation sensors,
automatically returned to
Use proper cleaning
sheet CPI supported
Bezel Lamp
starts Flashing
Bezel Lamp
keeps Flashing
the cleaning sheet is
insertion slot