Avtec MNL2201 Manuel de l'opérateur

Parcourez en ligne ou téléchargez le pdf Manuel de l'opérateur pour {nom_de_la_catégorie} Avtec MNL2201. Avtec MNL2201 4 pages. Simplespec ventilation systems

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
88 Armory Road, Vicksburg, MS 39183
888-994-7636, fax 888-864-7636
unifiedbrands.net
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the
consignee to inspect the container upon receipt of same and to determine
the possibility of any damage, including concealed damage. Unified
Brands suggests that if you are suspicious of damage to make a notation
on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
INSTALLATION INSTRUCTIONS
Avtec value ventilation hoods are provided with punched hanging brackets
designed to receive 1/2" threaded rod with a 1/2" nut and washer. Supporting
rods must be connected to all factory installed brackets. Recommended hanging
height is 6'-6" above finished floor for canopies. Low side wall ventilators should
be installed directly upon a Avtec base or on a fire rated wall. If wall mounted, the
bottom of the vent side panel should be 3' above finished floor.
ALL AVTEC VENTILATION SYSTEMS MUST BE INSTALLED IN ACCORDANCE
WITH NFPA-96, REMOVAL OF SMOKE AND GREASE LADEN VAPORS FROM
COMMERCIAL COOKING EQUIPMENT.
DISHWASHER/DISPLAY/BOX HOOD (SSA-DISH, SSA-ISLE, & SSA-BOX)
1. Check all local codes prior to installation. Special requirements may be
necessary depending upon building material construction.
2. Move crated hood to location of installation and very carefully uncrate hood.
3. Raise hood to proper hanging height.
4. Suspend hood from adequate roof supports using 1/2" threaded rods with
nuts and washers (See Fig. 1).
5. Level hood left to right and front to back.
6. Display hoods only: Slide chrome sleeve over all thread rod before securing
to hood/structure.
FRYER HOOD (SSA-FRYER)
1. Check all local codes prior to installation. Special requirements may be
necessary depending upon building material construction.
2. Move crated hood to location of installation and very carefully uncrate vent.
3. If vent is base mounted, base must be installed and leveled front to back and
left to right.
This manual provides information for:
SIMPLESPEC
VENTILATION SYSTEMS
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE: Due to a continuous program of product improvement, Unified Brands
reserves the right to make changes in design and specifications without prior notice.
NOTICE: Please read the entire manual carefully before installation. If certain
recommended procedures are not followed, warranty claims will be denied.
MODEL NUMBER _________________________
SERIAL NUMBER _________________________
INSTALLATION DATE ______________________
4. Place vent on wall, level front to back and left to right, then bolt metal
hanging bracket located on top of hood to wall (See Fig. 3).
5. Bottom of ventilator should be 32-34" above finished floor (See Fig. 2).
6. Fluid weld exhaust duct to hood exhaust duct collar (See Fig. 3).
FIGURE 1
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands
recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and
specifications. The company reserves the right of final interpretation of the user manual. Information subject to change
without notice. © 2022 Unified Brands. All Rights Reserved.