Table 17. Computer environment
Description
Temperature range
Relative humidity (maximum)
*
Vibration (maximum)
Shock (maximum)
Altitude (maximum)
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse when the hard drive is in use.

Service and support

NOTE:
For more details on Dell Service Plans, see
services.
Table 18. Warranty
Warranty
1 Year Basic Warranty with Hardware Service on site service after remote diagnosis
2 Years Basic Warranty Extension
3 Years Basic Warranty Extension
4 Years Basic Warranty Extension
5 Years Basic Warranty Extension
1 Year ProSupport and Next Business Day on-site service
2 Years ProSupport and Next Business Day on-site service
3 Years ProSupport and Next Business Day on-site service
4 Years ProSupport and Next Business Day on-site service
5 Years ProSupport and Next Business Day on-site service
1 Year ProSupport Plus for Client with Next Business Day on-site service
2 Years ProSupport Plus for Client with Next Business Day on-site service
3 Years ProSupport Plus for Client with Next Business Day on-site service
4 Years ProSupport Plus for Client with Next Business Day on-site service
5 Years ProSupport Plus for Client with Next Business Day on-site service
Table 19. Accidental damage services
Accidental Damage Services
1 Year Accidental Damage Service
2 Years Accidental Damage Service
3 Years Accidental Damage Service
4 Years Accidental Damage Service
Operating
10°C–35°C (50°F–95°F)
20% to 85% (non-condensing)
0.52 GRMS random at 5 Hz to 350 Hz
Bottom half-sine pulse with a change in
velocity of 50.8 cm/sec (20 in./sec)
3048 m (10,000 ft)
https://www.dell.com/learn/us/en/19/services/warranty-support-
Specifications of Precision 3440 Small Form Factor
Storage
-40°C-65°C (-40°F-149°F)
5% to 95% (non-condensing)
2.0 GRMS random at 5 Hz to 350 Hz
105G half-sine pulse with a change in
velocity of 133 cm/sec (52.5 in./sec)
10,668 m (35,000 ft)