Table 16. Touchpad specifications (continued)
Description
Horizontal
Vertical
Touchpad gestures
For more information about touchpad gestures for Windows, see the Microsoft knowledge base article
support.microsoft.com.

Battery

Table 17. Battery specifications
Description
Type
Voltage
Weight (maximum)
Dimensions:
Height
Width
Depth
Temperature range:
Operating
Storage
Operating time
Charging time
(approximate)
51 WHr, 3 cell, ExpressCharge™
11.40 VDC
250 g (0.55 lb)
7.05 mm (0.28 in.)
95.9 mm (3.78 in.)
181 mm (7.13 in.)
Charge: 0°C to 50°C, 32°F to
122°F; Discharge: 0°C to 60°C,
32°F to 139°F
-20°C to 60°C (-4°F to 140°F)
Varies depending on operating
conditions and can significantly
reduce under certain power-
intensive conditions.
● Standard charge: 0°C to 50°C:
4 hours
● Express Charge: 0°C to 15°C:
4 hours; 16°C to 45°C: 2
hours; 46°C to 50°C: 3 hours
Values
PCB: 101.7 mm/ active area: 99.5 mm
PCB: 55.2 mm/ active area: 53 mm
Values
68 WHr, 4 cell,
ExpressCharge™
15.2 VDC
340 g (0.75 lb)
7.05 mm (0.28 in.)
95.9 mm (3.78 in.)
233 mm (9.17 in.)
Charge: 0°C to 50°C, 32°F
to 122°F; Discharge: 0°C to
60°C, 32°F to 139°F
-20°C to 60°C (-4°F to
140°F)
Varies depending on operating
conditions and can significantly
reduce under certain power-
intensive conditions.
● Standard charge: 0°C to
50°C: 4 hours
● Express Charge: 0°C to
15°C: 4 hours; 16°C to
45°C: 2 hours; 46°C to
50°C: 3 hours
Control the charging time,
duration, start and end time,
and so on using the Dell
Power Manager application.
For more information on the
Dell Power Manager see on
https://www.dell.com/
4027871
at
68 WHr, 4 cell, Long Cycle Life
15.2 VDC
340 g (0.75 lb)
7.05 mm (0.28in.)
95.9 mm (3.78in.)
233 mm (9.17in.)
Charge: 0°C to 50°C, 32°F
to 122°F; Discharge: 0°C to
60°C, 32°F to 139°F
-20°C to 60°C (-4°F to
140°F)
Varies depending on operating
conditions and can significantly
reduce under certain power-
intensive conditions.
● Standard charge: 0°C to
50°C: 4 hours
● Express Charge: 0°C to
15°C: 4 hours; 16°C to
45°C: 2 hours; 46°C to
50°C: 3 hours
Control the charging time,
duration, start and end time,
and so on using the Dell
Power Manager application. For
more information on the Dell
Power Manager see on
https://
www.dell.com/
LLC battery
System information
19