Dell 3250 Manuel du produit - Page 20
Parcourez en ligne ou téléchargez le pdf Manuel du produit pour {nom_de_la_catégorie} Dell 3250. Dell 3250 37 pages. Product guide (.pdf)
Également pour Dell 3250 : Information Update (32 pages), Manuel du propriétaire (39 pages), Manuel du propriétaire (39 pages), Manuel de démarrage rapide (2 pages)
BIOS POST Error Codes and Messages
Error
Error Message and Character
Code
Attributes
142
PCI IO Allocation Error
DFLT/RED_BLACK
143
PCI IRQ Allocation Error
DFLT/RED_BLACK
144
Shadow of PCI ROM Failed
DFLT/RED_BLACK
145
PCI ROM not found
DFLT/RED_BLACK
146
Insufficient Memory to Shadow
PCI ROM DFLT/RED_BLACK
8100
Processor 01 failed BIST
WARN/YELLOW_BLACK
8101
Processor 02 failed BIST
WARN/YELLOW_BLACK
8110
Processor 01 Internal error
(IERR)
WARN/YELLOW_BLACK
8111
Processor 02 Internal error
(IERR)
WARN/YELLOW_BLACK
8120
Processor 01: Thermal trip
failure. WARN/YELLOW_BLACK
14
Pause on
Boot
Yes
PCI I/O Resource allocation for PCI devices has been
exceeded - remove add-adapter(s) retest. Suspect or
replace any add-in adapter(s) 1st, the PCI Riser 2nd
and the main board 3rd.
Yes
PCI IRQ Resource allocation for PCI devices has been
exceeded - remove add-adapter(s) retest. Suspect or
replace any add-in adapter(s) 1st, the PCI Riser 2nd
and the main board 3rd.
Yes
PCI ROM memory allocation area for PCI devices has
been exceeded - remove add-adapter(s) retest.
Suspect or replace any add-in adapter(s) 1st, the PCI
Riser 2nd and the main board 3rd.
Yes
PCI ROM memory allocation area for PCI devices has
been exceeded or PCI ROM did not have space to
load - remove add-adapter(s) retest. Suspect or
replace any add-in adapter(s) 1st, the PCI Riser 2nd
and the main board 3rd.
Yes
PCI Option ROM area exceeded - remove add-
adapter(s) retest. Suspect or replace any add-in
adapter(s) 1st, the PCI Riser 2nd and the main board
3rd.
Yes
Processor failed to initialize in time, Refer to "Fault
Resilient Boot" in Debug Methodology and failure
Isolation section.
Yes
Processor failed to initialize in time, Refer to "Fault
Resilient Boot" in Debug Methodology and failure
Isolation section.
Yes
Refer to "Processor" in Debug Methodology and failure
Isolation section.
Yes
Refer to "Processor" in Debug Methodology and failure
Isolation section.
Yes
Processor 01 has exceeded the thermal diode
temperature limit resulting in a thermal trip event,
check for airflow obstructions to fans and heat sinks.
Ensure processor air duct is present and secured. The
system is designed to run heavy loads up to 35C or
96F ambient. However, Under normal (i.e. no fan
failure) conditions, the CPU should not throttle until
42C/ 107F. (With a fan failure, throttling could possibly
occur at about 27C) Thermal trip should occur at 50C
/120F, thermal trip will shut down the processor or
system. If this occurs and the ambient temp is far
cooler - Refer to "Processor" in Debug Methodology
and failure Isolation section.
Intel® Server Platform SR870BH2
Failure
Revision 1.1