Dell Force10 C150 Manuel de démarrage rapide - Page 19
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Dell Force10 C150. Dell Force10 C150 33 pages. Quick start guide
Step
Task
On the C150, toggle the switch on the AC power supplies to the ON
3
(right) position.
On the C300, toggle the switch on the AC power supplies to the ON
(top) position.
On either system, toggle the switch on the DC power Over-Current
Protector ON
The power supply LEDs should be green. If these LEDs are not lit
4
green:
• Check that the unit is properly installed.
• Verify the power source.
• If the power supply cannot be verified, power off all modules and
replace the unit.
The fan tray LED should be green (online). You should be able to hear
5
the air flowing through the chassis. If the fans are not operating properly
or air is not flowing through the chassis:
• Power off all power supplies.
• Verify that the fan tray is properly installed.
• If the fan tray LED remains unlit, power down the unit, and replace the
fan tray.
After you supply power to the system, the following should occur:
•
The fan tray should be operating.
•
The green (online) fan tray, RPM, and line card LEDs should be lit and
remain lit as long as the system is receiving power and is operational.
When you supply power to the chassis, the system performs a series of power-on
self tests. RPM and line card LEDs blink as the diagnostic programs run. No
user interaction is required at this point. Observe the process on your console
monitor. When the boot process is complete, the card LEDs remain online
(green) and the console monitor displays the Command Line Interface (CLI)
prompt.
Installing the Hardware
17